SPECIFICATIONS
Adjust Pull Pressure – Loosen nut, turn knob clockwise to increase pressure or counter clockwise to reduce pressure. Once correct pressure is achieved, tighten nut.
Adjust Return Pressure – Loosen nut, using a hex key turn screw clockwise to increase pressure or counter clockwise to reduce pressure. Once correct pressure is achieved, tighten nut.
Hydraulic Oil – Use DEXRON III® or equivalent. Fill reservoir to 2” below the top.
Motor Voltage = 120VAC, 50/60HZ, 20 AMP Circuit.
Oil Temperature Operating Range = 0° F - 176° F (-17.8° C - 80° C) (Temperature should not exceed 180° F (82.2° C).